製品詳細:
起源の場所: 中国西安山西省
ブランド名: XZH TEST
証明: ISO
モデル番号: XHGG501A2
詳細情報
起源の場所:
中国西安山西省
ブランド名:
XZH TEST
証明:
ISO
モデル番号:
XHGG501A2
画面:
12.1インチタッチカラー液晶画面
サンプリング周波数:
400MHz
低電圧パルス振幅:
400V
ハイライト:

High Light

ハイライト:

ICE LV TDR Cable Fault Locator

,

TDR Cable Fault Locator 12" Windows System

,

12.1-inch touch color LCD screen

Trading Information
最小注文数量:
1セット
パッケージの詳細:
木製のパッケージ
受渡し時間:
5~8営業日
支払条件:
T/T
供給の能力:
3000台/年
製品の説明

Description

The 12" Windows System ICE LV TDR Cable Fault Locator is a precision instrument designed for detecting and locating faults in low-voltage cables. Its advanced Time Domain Reflectometry (TDR) technology provides accurate fault detection for efficient cable maintenance and troubleshooting.

Know more about power cables

 Power cables can be divided into:

Low-voltage cables (cables with voltage levels of 6kV and below). 

Medium-voltage cables (cables with voltage levels of 6kV and above, 35kV and below).

High-voltage cables (cables with voltage levels of 66kV and above).

And cable faults can be divided into open circuit faults, low resistance faults, leakage high resistance faults, and flashover high resistance faults according to their nature.

 

How to judge cable faults

In general, there are three ways to judge the nature of cable faults:

Judge by insulation resistance meter, multi-meter. 

Judge by cable pre-test results. 

Judge by "cable fault tester". Low-resistance and open-circuit faults (high-resistance) can be directly judged by the "low-voltage pulse method" test waveform of a multi-meter or a "cable fault tester".

 

Suitable for testing the faults of various cables

XHGG501-A TDR cable fault locator is a special instrument for measuring and analyzing power cable status and fault distance. It is suitable for testing low resistance, short circuit, open circuit breakage faults, leaking high resistance and flashover high resistance faults of power cables, coaxial cables, street light cables, buried wires, etc. 


Features

 

Pulse width

0.25uS/2uS/4uS  

Minimum resolution

0.1m  

Working conditions

Ambient temperature: -2565; Relative humidity: 90%; 12 Inch Windows System ICE LV TDR Cable Fault Locator 0

Ranging range

68km  


12 Inch Windows System ICE LV TDR Cable Fault Locator 1

The figure above shows the cable fault distance measured by the high-voltage flashover method ICE (ARC single-shot) test method.