Portable Power Cable Fault Locator for Outer Sleeve Failure and Rough Measurement

Portable Power Cable Fault Locator for Outer Sleeve Failure and Rough Measurement

製品詳細:
起源の場所: シアン・シャンシ
ブランド名: XZH TEST
証明: ISO
モデル番号: XHHG521C
詳細情報
起源の場所:
シアン・シャンシ
ブランド名:
XZH TEST
証明:
ISO
モデル番号:
XHHG521C
入力電圧:
AC220V(±10%)、50/60Hz(±2Hz)
Open-circuit電圧:
≥15000V
短絡の流れ:
≥50mA
位置決め率:
精度±(0.2%・L±1)メートル
ハイライト:

High Light

ハイライト:

Outer Sleeve Failure Cable Fault Locator

,

Rough Measurement Power Cable Fault Detector

,

Portable Cable Fault Tester

Trading Information
最小注文数量:
1セット
パッケージの詳細:
木製のパッケージ
受渡し時間:
5~8営業日
支払条件:
T/T
供給の能力:
3000台/年
製品の説明
XHHG521C
Specialized equipment for detecting outer sleeve failures and performing rough measurements in power cables.
The equipment uses a switching power supply to form a high-voltage constant current source, with an open-circuit voltage of 15000V and a short-circuit current of 50mA.
 It employs a high-sensitivity amplifier and galvanometer for balance indication, forming a balanced bridge with a proportional potentiometer.
The entire system is positioned at a high potential. The measuring cable is a specially designed double-core high-voltage rubber cable, and a four-terminal resistance measurement method is used to avoid errors introduced by lead resistance. The cable is reliably grounded through a braided shielding layer. The operating buttons on the panel are at a low potential, and the bridge is operated via an insulated rod. The high-voltage constant current source and bridge are integrated into a portable aluminum alloy case. Therefore, this equipment features high voltage, light weight, convenient operation, and safe use.
Key Applications
  • Detection of outer sleeve failures in power cables
  • Rough measurement of fault locations
  • Maintenance and troubleshooting of cable infrastructure


    Portable Power Cable Fault Locator for Outer Sleeve Failure and Rough Measurement 0

Instrument Usage Precautions


1. Do not touch the high-voltage connection line or the cable under test during testing to avoid injury from high voltage;

2. Do not turn on the instrument while connecting the cable, and turn off the power immediately after the test;

3. The instrument cannot be started when the voltage adjustment is not at zero;

4. At least two people should be present during use. One person connects the wires, and the other checks them. The test can begin only after everything is accurate;

5. The instrument's grounding terminal must be reliably grounded. Use a dedicated grounding wire, preferably clamped to grounding posts in the test field, grounding bars in electrical cabinets, or the feet of mechanical equipment.

Portable Power Cable Fault Locator for Outer Sleeve Failure and Rough Measurement 1