High Voltage Surge Generator with Built-in 2μF Capacitor and 1225J Discharge Power

High Voltage Surge Generator with Built-in 2μF Capacitor and 1225J Discharge Power

製品詳細:
起源の場所: 中国・陝西省西安
ブランド名: XZH TEST
証明: ISO CE
モデル番号: XHHV535-2T
詳細情報
起源の場所:
中国・陝西省西安
ブランド名:
XZH TEST
証明:
ISO CE
モデル番号:
XHHV535-2T
ハイライト:

High Light

ハイライト:

Built-in capacitor 2μF High Voltage Surge Generator

,

Discharge power 1225J HV Surge Generator

,

High Voltage Surge Generator

Trading Information
最小注文数量:
1セット
パッケージの詳細:
木製梱包
受渡し時間:
5~8営業日
支払条件:
T/T
供給の能力:
3000台/年
製品の説明

Description

When the XHHV535-2T trolley-type high-voltage surge generator is in use, after selecting the function switch, press the start button to perform high-voltage boosting work. After use, press the stop button, and the internal system will automatically release the remaining high voltage on the accumulator.

 

The device also has the function of zero-start protection, which can make the operation of the device more safe and reliable. It has super short-circuit protection function, which can make the high-voltage output work directly to the ground.


Technical parameters

Impact high voltage

035kV

High voltage partial pressure

2.5 level

Built-in capacitor

2μF

Discharge power

1225J

Impact power

2000W

Output voltage polarity

negative polarity

Impact time

about 7 seconds for automatic impact, arbitrary control time for manual impact

Over current protection

10A (more than 5 seconds) Low voltage side

Power supply

AC220V±10%, 50Hz±2Hz(60Hz)

Ambient temperature

-20+60


Back panel

High Voltage Surge Generator with Built-in 2μF Capacitor and 1225J Discharge Power 0

1. Sampling ground: The negative end of the pulse energy storage capacitor has a high voltage and must be reliably grounded. It is used for sampling when sampling waveforms under high-voltage flashover conditions of the cable fault tester. (Reliable grounding is still required for non-high-voltage flashover sampling).

2. High-voltage ground: Also known as the high-voltage tail, it must be reliably grounded to prevent high-voltage leakage and discharge. Poor contact may result in failure to boost voltage, high-voltage breakdown and damage to internal devices of the instrument, and internal leakage or discharge of the instrument causing safety accidents.

3. High-voltage output (HV OUT): Dedicated DC high-voltage output terminal.