XHHD530M  Low voltage concealed cable tester


Description

The hidden line fault detector is a specialized instrument designed for power, broadcasting, post and telecommunications departments, as well as industrial and mining enterprises and rural areas to locate underground cables, including direct buried armored cable lines and buried line faults. It is capable of detecting the direction of the buried line, the precise underground position, the basic burial depth, and various types of ground leakage faults and broken core faults. This includes lines buried under paddy fields, cement roads, brick and stone surfaces, asphalt roads, and within the walls of buildings. Waterproof wires and cables used above ground can also be detected using this instrument with appropriate methods.


Transmitter

The transmitter panel is equipped with "power switch", "power indication"; "output selection", "high, medium, low"; "output indication" and "K measurement" switching switches, and the indicator light indicates the switching position; "output·KΩ measurement" shares an output terminal, which is switched by the "output·indication" and "KΩ measurement" switches; set "output 2" output terminal; square meter head indicates output and KΩ resistance. It can check the line on, off, mixed, and measure the size of the ground leakage resistance.

Output signal form

pulse period 1.34±0.15mS. Width 0.2 ±0.1mS intermittent period 1.8±1S.

Output voltage

pulse period Upp high range greater than 1000V, medium range greater than 60V, low range greater than 30V.

KΩ measurement

It can check the side line on, off, mixed and leakage group size, and determine the nature of the fault.

The "output 2" output terminal

It can output peak pulse short-circuit current 1-5A.

Output power

Pulse power greater than 2.5W (when high-end load resistance is 80KΩ).

Power supply

8.4V.


Instrument principle and structure

This instrument consists of a transmitter, a receiver, a probe and a head, a pair of plugs and plugs, connecting wires, etc.

Transmitter (1) Mainly outputs continuous pulse signals, which is the signal source for finding faults. (2) kΩ function, can detect the continuity, disconnection, mixing and leakage resistance of the line, and determine the nature and type of fault. (3) "Output 2" output terminal outputs large current


Packing list

Item

Name

Qty.

1

Transmitter

1

2

Receiver

1

3

Probe

1

4

Probe head

1

5

Insert rod(red black)

2

6

Connection lines

2

7

Charger

1