logo
ホーム > 製品 >
キャベルの故障検出器
>
35kV Cable Fault Locator and Cable Sheath Fault Detector for Outer Sleeve Failure

35kV Cable Fault Locator and Cable Sheath Fault Detector for Outer Sleeve Failure

製品詳細:
起源の場所: シアン・シャンシ
ブランド名: XZH TEST
証明: ISO CE
モデル番号: XHHG520
詳細情報
起源の場所:
シアン・シャンシ
ブランド名:
XZH TEST
証明:
ISO CE
モデル番号:
XHHG520
ハイライト:

High Light

ハイライト:

Outer Sleeve Failure Cable Fault Locator

,

Cable Sheath Fault Detector

,

35kV Cable Fault Locator

Trading Information
最小注文数量:
1セット
パッケージの詳細:
木製のパッケージ
受渡し時間:
5~8営業日
支払条件:
T/T
供給の能力:
3000台/年
製品の説明
XHHG520
The Cable Fault Locator is designed for precise detection of outer sleeve failures in cables, providing accurate fault location to minimize downtime and maintenance costs.
The equipment uses an electric voltage regulator and an R-type transformer to form a high-voltage constant current source, with keypad operation for voltage increase and decrease. The open-circuit voltage is 15kV, and the short-circuit current is 100mA. A high-sensitivity amplifier and galvanometer indicate balance, forming a balanced bridge with a proportional potentiometer, and the entire unit is positioned at a high potential. The measuring cable is a specially designed double-core high-voltage rubber cable, and a four-terminal resistance measurement method is used to avoid errors introduced by lead resistance. The entire panel is positioned at a low potential. One-button operation allows for automatic calculation of the cable length and fault distance. The high-voltage source and bridge are integrated into a portable protective case. Therefore, this equipment features high voltage, light weight, convenient operation, and safe use.
Key Features
  • Accurate detection of outer sleeve failures
  • Precise fault location capabilities
  • Designed for efficient cable maintenance
  • Reduces system downtime and repair costs
Technical Specifications
Bridge Section Open-circuit voltage  ≥15kV

Short-circuit current  ≥100mA (recommended setting: 5~40mA during balancing)

Positioning ratio  accuracy ±(0.2%·L±1) meters
Voltage and Positioning Section Input voltage 220V (±10%), 50Hz (±2Hz)

Output voltage 0~15kV (square wave) adjustable

Output current 0~200mA

Output capacity 2kVA

35kV Cable Fault Locator and Cable Sheath Fault Detector for Outer Sleeve Failure 0

35kV Cable Fault Locator and Cable Sheath Fault Detector for Outer Sleeve Failure 1